快能纺机网资讯
    博科光纤交换机升级微码方法
    发布者:brocade  发布时间:2011-11-21 10:42:25  访问次数:1279

     博科光纤交换机升级微码方法: 博科光纤交换机光纤模块升级微码资源准此处以Brocade <32R1812>交换机为例,此方法也适用于其他博科光纤交换机。

    Brocade 5040交换机现有微码版本v6.1.1.b升级至v6.2.2b,具体操作步骤如下:

    1 资源准备:网线一根,BROCADE 32R1812 firmware version v6.2.2b,控制台(PC或笔记本),要安装Java JRE 1.5版本以上

    2 设备连接:用网线将控制台(PC 或笔记本)的网卡连接到BCH管理口上就行。
    (然后去AMM查看IO的光纤交换模块的IP地址)

    3 控制台环境设置:将控制台的网卡IP地址设备为192.168.70.139,子网掩码为255.255.255.0。然后在控制台的安装FTP服务或软件,FTP的根目录设置为v6.2.2b软件所在的目录,并设置一个用户root,密码为root。确认控制台与交换机(brocade)的网络连接正常。执行以下命令:

    Ping 192.168.70.139
    注:笔记本上装FTP以一去测一下,读写权限勾上、在另外台机器去访问FTP、如果可以就能看到文件、并且在当前目录有权限读写、这样就OK了、另外我上面只的IP跟你在AMM 光纤交换随着相应的设置改变而改变。
    注:FTP账户和密码最好改成和交换机登录时的密码一样、比如默认是用户:USERID 密码:PASSW0RD这样会使你更新完微码登入不到交换机里。

    4 登陆交换机:输入telnet 192.168.70.139 ,用户名为:USERID,密码为:PASSW0RD,登录到交换机。登陆进入后,会提示更改admin帐户的密码,如需更改直接回车,不更改则按ctrl + c

    5 登录后输入firmwareshow,回车,可以查看现有的微码版本,如果不是v6.2.2b,则需要升级到v6.2.2b

    6 升级操作:输入firmwaredownload,回车,依据下面操作日志进行操作

    *ftp搭建并且能访问到自己的文件这就OK

    swd77:USERID> firmwaredownload
    Server Name or IP Address: 192.168.70.139
    (放微码文件的ftp地址)
    User Name: USERID
    ftp用户名)
    File Name: /release.plist
    (微码文件名)
    Network Protocol(1-auto-select, 2-FTP, 3-SCP) [1]: 2
    (选择传输方式)
    Password:
    (此处输入FTP帐户密码后回车)
    Checking system settings for firmwaredownload...
    Protocol selected: FTP
    Trying address-->AF_INET IP: 192.168.70.139, flags : 2
    System settings check passed.

    This command will upgrade the firmware on both CP blades. If you want to
    upgrade firmware on a single CP only, please use -s option.

    You may run firmwaredownloadstatus to get the status of this
    command.

    This command will cause a warm/non-disruptive boot on the active CP,
    but will require that existing telnet, secure telnet or SSH sessions
    be restarted.


    Do you want to continue [Y]: y
    Firmware is being downloaded to standby CP. This step may take up to 30 minutes.
    Firmware has been downloaded successfully to Standby CP.
    Standby CP is going to reboot with new firmware.
    Standby CP booted successfully with new firmware.
    Connection closed.

    这时交换机将自动进行微码升级,无须人工干预,此过程大概需要20-30分钟。

    7 升级完后,用firmwareshow查看版本是否为v6.2.2b
    更新完以后在更新另外的光纤交换就行、因为之前我更新了一下而另外的一个也就自己跟着更新了、结果不是、所以呢你还得在更新另外一个。OK